Heath-consultants Detecto Pak-Infrared (DP-I) Bedienungsanleitung Seite 7

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 35
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 6
102105-0 DP-IR MANUAL REV M
Page 7 of 35
Detection Method: Infrared Controlled Interface Polarization Spectrometer
Measurement Range: 0-100,000 PPM
1-100% Gas
Display Range: Auto Ranging: Manual Ranging:
PPM: 0-10,000 PPM scale: 0-10,000
% Gas: 1-100% % Gas: 0-100%
Sensitivity: 0-1000 PPM: 1 PPM
1000-10,000 PPM: 5 PPM
1-100% Gas: 0.5%
Accuracy: Greater of +/- .5% or +/- 10% of reading (typical, std conditions)
(% Gas on manual mode)
Detection Alarms Modes: Digital Methane Detection (DMD):
Audible tone when detection threshold is exceeded
Adjustable Alarm Level from 1 to 9000 PPM
Tick:
Continuous audio tone relative to concentration
System Fault Warning: Audible tone and indication on the display
Self-Test & Calibration: Built in Self-Test and Calibration function veries operation and
adjusts calibration for maximum sensitivity. Test gas cell integrated
within the instrument.
Compliance: EN 61326-1
Conducted Emissions Class B EN 61326-1
Radiated Emissions Class B EN 61000-4-2 4kV/8kV
ANSI C63.4 Class B EN 61000-4-3 3 V/M
FCC 47 CFR Part 15 Class B
Dust Filter: Replaceable lter provides dust protection. Easy change out quick
disconnect lter cap.
Display: Large easy to read backlit LCD (.75” Numeric)
Operating Temperature: 0 to + 122° F (-17 to 50° C) (nominal battery voltage)
Humidity: 5 to 95% RH, non-condensing
Enclosure: IP54 (Water splash and Dust resistant)
Instrument Weight: 5.6 lbs.
Carrying Case: 13 lbs. empty; 21 lbs. lled
24.5” x 21” x 9”
Power Supply: Internal rechargeable Li-ion battery or
External 12 VDC car battery with optional power conditioner
Battery Operating Life: 8 hours at 32° F with out backlight on
Battery Charger: External, in-line, 110 - 240 VAC, 50/60 hertz. 10 hours to 90%
charge
Shoulder Strap: Single over the shoulder padded strap
Speaker Volume: 108 dBs @ Alarm port (A-fast)
Survey Probe: Quick connect tting with locking clasp. Adjustable length from
25” to 41”
Bar hole Probe: Std: 20”; Optional 36”
Intrinsic Safety: Class 1 Division 1 Group D T3
UL 913 MetLab #E112840
CHAPTER I
DP-IR System Specications
Seitenansicht 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 34 35

Kommentare zu diesen Handbüchern

Keine Kommentare